Oil-immersed transformers

Product Introduction

Product Features

Strong Economic Performance

The transformer provides excellent energy-saving performance. Compared with conventional products, the average no-load current is reduced by approximately 60% to 80%, while the average no-load loss is reduced by approximately 25% to 35%.

Extended Service Life

The transformer oil tank adopts a fully sealed structure. The tank cover and tank body can be connected by bolts or welded along the edges.

Because the transformer oil is completely isolated from the surrounding air, oil aging is reduced and the service life of the transformer is extended.

Reliable Operation

The sealing components of the oil tank have been improved to increase operating reliability. The manufacturing and sealing processes are also optimized to ensure dependable sealing performance.

Compact Installation

The transformer oil tank uses corrugated plate radiators. As the oil temperature changes, the corrugated plates expand and contract, performing the function of an oil conservator.

The corrugated oil tank has an attractive appearance, a compact structure and a small installation footprint.

Technical Data of S11 Series

S11(M)-630~31500/35 Low-Loss and Off-Circuit Tap-Changing Transformer

Rated Capacity (kVA) HV (kV) Tapping Range LV (kV) Vector Group No-Load Loss (W) On-Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%)
630 35 ±5% 3.15 / 6.3 / 10.5 Yd11 830 7870 6.5 1.10
800 35 ±5% 3.15 / 6.3 / 10.5 Yd11 980 9410 6.5 1.00
1000 35 ±5% 3.15 / 6.3 / 10.5 Yd11 1150 11540 6.5 1.00
1250 35 ±5% 3.15 / 6.3 / 10.5 Yd11 1410 13940 6.5 0.90
1600 35 ±5% 3.15 / 6.3 / 10.5 Yd11 1700 16670 6.5 0.80
2000 35 ±5% 3.15 / 6.3 / 10.5 Yd11 2180 18380 6.5 0.70
2500 35 ±5% 3.15 / 6.3 / 10.5 Yd11 2560 19670 6.5 0.60
3150 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 3040 23090 7.0 0.56
4000 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 3620 27360 7.0 0.56
5000 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 4320 31380 7.0 0.48
6300 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 5250 35060 7.0 0.48
8000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 7200 38480 7.5 0.42
10000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 8700 45320 8.0 0.42
12500 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 10080 53870 8.0 0.40
16000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 12160 65840 8.0 0.40
20000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 14400 79520 8.0 0.40
25000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 17020 94050 8.0 0.32
31500 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 20220 112860 8.0 0.32

S11(M)-630~31500/35 Low-Loss and Off-Circuit Tap-Changing Transformer

Rated Capacity (kVA) HV (kV) Tapping Range LV (kV) Vector Group No-Load Loss (W) On-Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%)
630 35 ±5% 3.15 / 6.3 / 10.5 Yd11 830 7870 6.5 1.10
800 35 ±5% 3.15 / 6.3 / 10.5 Yd11 980 9410 6.5 1.00
1000 35 ±5% 3.15 / 6.3 / 10.5 Yd11 1150 11540 6.5 1.00
1250 35 ±5% 3.15 / 6.3 / 10.5 Yd11 1410 13940 6.5 0.90
1600 35 ±5% 3.15 / 6.3 / 10.5 Yd11 1700 16670 6.5 0.80
2000 35 ±5% 3.15 / 6.3 / 10.5 Yd11 2180 18380 6.5 0.70
2500 35 ±5% 3.15 / 6.3 / 10.5 Yd11 2560 19670 6.5 0.60
3150 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 3040 23090 7.0 0.56
4000 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 3620 27360 7.0 0.56
5000 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 4320 31380 7.0 0.48
6300 35–38.5 ±5% 3.15 / 6.3 / 10.5 Yd11 5250 35060 7.0 0.48
8000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 7200 38480 7.5 0.42
10000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 8700 45320 8.0 0.42
12500 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 10080 53870 8.0 0.40
16000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 12160 65840 8.0 0.40
20000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 14400 79520 8.0 0.40
25000 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 17020 94050 8.0 0.32
31500 35–38.5 ±2 × 2.5% 3.15 / 3.3 / 6.3 / 6.6 / 10.5 / 11 Ynd11 20220 112860 8.0 0.32

S11(M)-30~1600/10 Low-Loss and Off-Circuit Tap-Changing Transformer

Rated Capacity (kVA) HV (kV) Tapping Range LV (kV) Vector Group No-Load Loss (W) On-Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%)
30 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 100 630 / 600 4.0 0.80
50 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 130 910 / 870 4.0 0.75
63 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 150 1090 / 1040 4.0 0.75
80 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 180 1310 / 1250 4.0 0.70
100 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 200 1580 / 1500 4.0 0.65
125 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 240 1890 / 1800 4.0 0.65
160 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 280 2310 / 2200 4.0 0.60
200 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 340 2730 / 2600 4.0 0.50
250 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 400 3200 / 3050 4.0 0.50
315 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 480 3830 / 3650 4.0 0.45
400 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 570 4520 / 4300 4.0 0.45
500 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 680 5410 / 5150 4.0 0.40
630 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 810 6200 4.5 0.40
800 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 980 7500 4.5 0.35
1000 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 1150 10300 4.5 0.35
1250 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 1360 12000 4.5 0.30
1600 6 / 6.3 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Dyn11 / Yyn0 1640 14500 4.5 0.30

Amorphous Alloy Transformer

Model HV (kV) HV Tap Range LV (kV) Connection Symbol No-Load Loss (W) Load Loss at 100°C (W) No-Load Current (%)
SBH15-30 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 33 630 1.5
SBH15-50 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 43 910 1.2
SBH15-63 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 50 1090 1.1
SBH15-80 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 60 1310 1.0
SBH15-100 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 75 1580 0.9
SBH15-125 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 85 1890 0.8
SBH15-160 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 100 2310 0.6
SBH15-200 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 120 2730 0.6
SBH15-250 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 140 3200 0.6
SBH15-315 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 170 3830 0.5
SBH15-400 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 200 4520 0.5
SBH15-500 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 240 5410 0.5
SBH15-630 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 320 6200 0.3
SBH15-800 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 380 7500 0.3
SBH15-1000 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 450 10300 0.3
SBH15-1250 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 530 12000 0.2
SBH15-1600 6 / 6.3 / 10 ±5% or ±2 × 2.5% 0.4 Dyn11 630 14500 0.2

About Yawei

Yawei Group has more than 3,000 employees, including over 300 engineering and technical personnel. The company covers an area of more than 1,200 mu, and the Group’s sales revenue in 2025 was approximately RMB 6 billion. Among them, Jiangsu Yawei Transformer Co., Ltd. achieved annual sales of more than RMB 2.4 billion.

Request a Quote

Order Process

1️⃣Submit Your Requirements

Send us the required transformer type, capacity, voltage, frequency, standards, installation environment, and project details.

2️⃣ Technical Review & Solution Confirmation

Our engineers review your specifications, recommend the appropriate transformer solution, and confirm the technical parameters, drawings, price, and delivery time.

3️⃣ Production & Factory Testing

After order confirmation, we arrange production according to the approved technical documents. Each transformer undergoes strict inspection and routine testing before shipment.

4️⃣Delivery & After-Sales Support

We arrange secure packaging and international shipping, provide complete technical documents, and offer installation guidance and after-sales support.

Professional. Reliable. Project-Focused.

Frequently Asked Questions

We manufacture power transformers, oil-immersed transformers, dry-type transformers, amorphous alloy transformers, pad-mounted transformers, renewable energy transformers, prefabricated substations, and various special-purpose transformers.
Yes. We can customize the transformer capacity, input and output voltage, frequency, vector group, cooling method, enclosure, accessories, protection level, and applicable standards according to your project specifications.
Please provide the transformer type, rated capacity, primary and secondary voltage, frequency, number of phases, vector group, impedance, cooling method, installation environment, required standards, quantity, and destination port.
Our transformers can be designed and manufactured according to applicable international and regional standards, including IEC and other project-specific requirements. Different product series may also comply with UL, CE, TÜV, KEMA, and GOST requirements.
Each transformer undergoes strict inspection and routine testing before shipment. Depending on the project, type tests and special tests can also be arranged according to the agreed technical standards.
The production time depends on the transformer type, capacity, technical complexity, quantity, and testing requirements. A detailed delivery schedule will be confirmed after the technical specifications and order are approved.
Yes. We can provide approved drawings, technical data sheets, test reports, packing lists, operation manuals, and other documents required for installation, customs clearance, and project acceptance.
Transformers are securely packed according to their size, structure, and transportation method. Moisture protection, shock protection, reinforced packaging, and suitable export markings can be provided to reduce the risk of damage during transportation.
Yes. We provide remote technical guidance, installation instructions, commissioning support, troubleshooting assistance, and after-sales service. On-site support can also be discussed according to the project requirements.
Send us your technical specifications, drawings, or project requirements. Our engineering team will review the information, recommend a suitable solution, and provide a quotation, technical proposal, and estimated delivery time.

Related Products

Request a quote