Dry-type transformer

Product Introduction

The transformer offers safe, flame-retardant and fire-resistant performance without causing pollution, making it suitable for direct installation at the load center.

It requires little maintenance, is easy to install and helps lower overall operating costs.

The product provides excellent moisture resistance and can operate normally in environments with up to 100% humidity. After shutdown, it can be restarted without pre-drying.

It features low loss, low partial discharge, low noise and strong heat dissipation. Under forced-air cooling conditions, it can operate at up to 150% of its rated load.

A complete temperature protection and control system provides reliable protection for safe transformer operation.

Based on operating studies of products already in service, the transformer has achieved an internationally advanced level of reliability.

Technical Data of SCB10 Series

SCB10-50~2500/35 Epoxy-Resin Dry-Type Transformer

 

Rated Capacity (kVA) HV (kV) HV Tapping Range LV (kV) Vector Group No-Load Loss (W) On-Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%)
50 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 500 1500 6.0 2.8
100 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 700 2200 6.0 2.4
160 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 880 2960 6.0 1.8
200 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 980 3500 6.0 1.8
250 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1100 4000 6.0 1.6
315 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1310 4750 6.0 1.6
400 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1530 5700 6.0 1.4
500 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1800 7000 6.0 1.4
630 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2070 8100 6.0 1.2
800 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2400 9600 6.0 1.2
1000 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2700 11000 6.0 1.0
1250 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3150 13400 6.0 0.9
1600 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3600 16300 6.0 0.9
2000 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 4250 19200 6.0 0.9
2500 35–38.5 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 4950 23000 6.0 0.9

SCB10-50~2500/20 Epoxy-Resin Dry-Type Transformer

Rated Capacity (kVA) HV (kV) HV Tapping Range LV (kV) Vector Group No-Load Loss (W) On-Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%)
50 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 380 1300 6.0 2.4
100 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 600 2100 6.0 2.2
160 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 750 2600 6.0 1.8
200 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 820 3100 6.0 1.8
250 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 940 3600 6.0 1.6
315 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1080 4300 6.0 1.6
400 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1280 5100 6.0 1.4
500 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1500 6100 6.0 1.4
630 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1700 7200 6.0 1.2
800 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1950 8700 6.0 1.2
1000 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2300 10300 6.0 1.0
1250 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2650 12150 6.0 1.0
1600 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3100 14600 6.0 1.0
2000 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3600 17250 8.0 0.8
2500 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 4300 20400 8.0 0.8
2000 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3600 18800 8.0 0.8
2500 20 / 22 / 24 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 4300 22400 8.0 0.8

SCB10-30~2500/10 Epoxy-Resin Dry-Type Transformer

Rated Capacity (kVA) HV (kV) HV Tapping Range LV (kV) Vector Group No-Load Loss (W) On-Load Loss (W) Short-Circuit Impedance (%) No-Load Current (%)
30 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 190 710 4.0 2.4
50 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 270 1000 4.0 2.4
80 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 370 1380 4.0 1.8
100 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 400 1570 4.0 1.8
125 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 470 1850 4.0 1.6
160 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 540 2130 4.0 1.6
200 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 620 2530 4.0 1.4
250 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 720 2760 4.0 1.4
315 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 880 3470 4.0 1.2
400 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 980 3990 4.0 1.2
500 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1160 4880 4.0 1.2
630 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1340 5880 4.0 1.0
630 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1300 5960 6.0 1.0
800 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1520 6960 6.0 1.0
1000 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 1770 8130 6.0 1.0
1250 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2090 9690 6.0 1.0
1600 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2450 11730 6.0 1.0
2000 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3050 14450 6.0 0.8
2500 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3600 17170 6.0 0.8
1600 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 2450 12960 8.0 1.0
2000 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±5%, ±2 × 2.5% 0.4 Yyn0 / Dyn11 3050 15960 8.0 0.8

Amorphous Alloy Transformer

Model HV (kV) HV Tap LV (kV) Connection Symbol No-Load Loss (W) Load Loss at 120°C (W) No-Load Current (%)
SCBH15-100 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 130 1570
SCBH15-160 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 170 2125
SCBH15-200 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 200 2525 0.8
SCBH15-250 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 230 2755 0.8
SCBH15-315 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 280 3470 0.7
SCBH15-400 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 300 3985 0.7
SCBH15-500 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 360 4880 0.6
SCBH15-630 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 420 5875 0.5
SCBH15-800 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 480 6955 0.5
SCBH15-1000 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 550 8125 0.4
SCBH15-1250 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 660 9690 0.4
SCBH15-1600 6 / 6.3 / 6.6 / 10 / 10.5 / 11 ±2 × 2.5%, ±3 × 2.5% 0.4 Dyn11 / Yyn0 750 11730 0.4

About Yawei

Yawei Group has more than 3,000 employees, including over 300 engineering and technical personnel. The company covers an area of more than 1,200 mu, and the Group’s sales revenue in 2025 was approximately RMB 6 billion. Among them, Jiangsu Yawei Transformer Co., Ltd. achieved annual sales of more than RMB 2.4 billion.

Request a Quote

Order Process

1️⃣Submit Your Requirements

Send us the required transformer type, capacity, voltage, frequency, standards, installation environment, and project details.

2️⃣ Technical Review & Solution Confirmation

Our engineers review your specifications, recommend the appropriate transformer solution, and confirm the technical parameters, drawings, price, and delivery time.

3️⃣ Production & Factory Testing

After order confirmation, we arrange production according to the approved technical documents. Each transformer undergoes strict inspection and routine testing before shipment.

4️⃣Delivery & After-Sales Support

We arrange secure packaging and international shipping, provide complete technical documents, and offer installation guidance and after-sales support.

Professional. Reliable. Project-Focused.

Frequently Asked Questions

We manufacture power transformers, oil-immersed transformers, dry-type transformers, amorphous alloy transformers, pad-mounted transformers, renewable energy transformers, prefabricated substations, and various special-purpose transformers.
Yes. We can customize the transformer capacity, input and output voltage, frequency, vector group, cooling method, enclosure, accessories, protection level, and applicable standards according to your project specifications.
Please provide the transformer type, rated capacity, primary and secondary voltage, frequency, number of phases, vector group, impedance, cooling method, installation environment, required standards, quantity, and destination port.
Our transformers can be designed and manufactured according to applicable international and regional standards, including IEC and other project-specific requirements. Different product series may also comply with UL, CE, TÜV, KEMA, and GOST requirements.
Each transformer undergoes strict inspection and routine testing before shipment. Depending on the project, type tests and special tests can also be arranged according to the agreed technical standards.
The production time depends on the transformer type, capacity, technical complexity, quantity, and testing requirements. A detailed delivery schedule will be confirmed after the technical specifications and order are approved.
Yes. We can provide approved drawings, technical data sheets, test reports, packing lists, operation manuals, and other documents required for installation, customs clearance, and project acceptance.
Transformers are securely packed according to their size, structure, and transportation method. Moisture protection, shock protection, reinforced packaging, and suitable export markings can be provided to reduce the risk of damage during transportation.
Yes. We provide remote technical guidance, installation instructions, commissioning support, troubleshooting assistance, and after-sales service. On-site support can also be discussed according to the project requirements.
Send us your technical specifications, drawings, or project requirements. Our engineering team will review the information, recommend a suitable solution, and provide a quotation, technical proposal, and estimated delivery time.